CVE-2022-41645

Severity: HIGH

Description: Out-of-bounds read vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.

CVSS Score: N/A

Priority

D

CISA Data

EPSS Data

  • EPSS: 0.000970000
  • Percentile: 0.266090000
  • Date: 2026-06-01

ExploitDB

No data available.

HackerOne Data

  • Rank: 9606
  • Reports submitted count: 0
  • Unknown: 0
  • None: 0
  • Low: 0
  • Medium: 0
  • High: 0
  • Critical: 0

GitHub PoCs

    Nuclei Templates

    No data available.

    VulnCheck Data

    Affected Products:

    • FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd. V-Server - Versions: v4.0.12.0 and earlier

    References:

    Risk Assessment

    1. Risk Assessment
    The vulnerability CVE-2022-41645 is an out-of-bounds read vulnerability in FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd.’s V-Server software, specifically versions v4.0.12.0 and earlier. This means a specially crafted project file can cause the software to read data beyond the allocated memory buffer. The risk is considered high, with a CVSS v3.1 score of 7.8. The business impact stems from potential information disclosure, arbitrary code execution, and potential disruption of operations if the V-Server is critical to business processes. The likelihood of exploitation is moderate, as it requires a local attacker to get a user to open a malicious project file, but the ease of exploitation is relatively low once the file is opened. Confidentiality, integrity, and availability are all potentially impacted, as the attacker could read sensitive data, modify data in memory, or crash the V-Server application. The EPSS score of 0.000970000 suggests a low, but non-zero, probability of exploitation in the wild.

    2. Potential Attack Scenarios
    A potential attack scenario involves a malicious actor targeting engineers using V-Server for project development. The attacker crafts a specially designed project file containing the out-of-bounds read trigger. They then deliver this project file to a user, perhaps through email or a shared network drive, disguised as a legitimate project. When the user opens the crafted project file within V-Server, the out-of-bounds read occurs. This allows the attacker to read sensitive information stored in adjacent memory locations, potentially including configuration details or user credentials. In a more severe case, the attacker could leverage the read to gain control of the execution flow and inject arbitrary code, leading to full system compromise. The outcome could range from data theft to complete control of the V-Server application and potentially the underlying system.

    3. Mitigation Recommendations
    The primary mitigation for CVE-2022-41645 is to upgrade V-Server to a version later than v4.0.12.0. FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd. should be consulted for the latest version and update instructions. As an immediate short-term mitigation, users should exercise caution when opening project files from untrusted sources. Implement a review process for project files before opening, and consider limiting user privileges to reduce the potential impact of a successful exploit. Regularly back up V-Server project data to ensure recoverability in case of data corruption or compromise. Relevant resources include the official FUJI ELECTRIC website: https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php and the JVN vulnerability report: https://jvn.jp/en/vu/JVNVU92811888/index.html.

    4. Executive Summary
    V-Server, a product from FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd., is vulnerable to an out-of-bounds read issue (CVE-2022-41645). This vulnerability could allow a local attacker to steal sensitive information or even gain control of the V-Server application by tricking a user into opening a specially crafted project file. The risk is considered high, potentially impacting the confidentiality, integrity, and availability of data and systems. We recommend upgrading V-Server to the latest version as soon as possible to mitigate this risk. Users should also be cautious when opening project files from external sources. Addressing this vulnerability is critical to protecting our data and ensuring the continued smooth operation of processes reliant on V-Server. Prompt action will minimize the potential for disruption and data compromise.

    CVE-2022-47317

    Severity: HIGH

    Description: Out-of-bounds write vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.

    CVSS Score: N/A

    Priority

    D

    CISA Data

    EPSS Data

    • EPSS: 0.000970000
    • Percentile: 0.266230000
    • Date: 2026-05-29

    ExploitDB

    No data available.

    HackerOne Data

    • Rank: 9580
    • Reports submitted count: 0
    • Unknown: 0
    • None: 0
    • Low: 0
    • Medium: 0
    • High: 0
    • Critical: 0

    GitHub PoCs

      Nuclei Templates

      No data available.

      VulnCheck Data

      Affected Products:

      • FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd. V-Server - Versions: v4.0.12.0 and earlier

      References:

      Risk Assessment

      1. Risk Assessment
      The vulnerability, an out-of-bounds write in V-Server versions v4.0.12.0 and earlier, presents a moderate to high risk. The nature of the vulnerability allows a local attacker, with user interaction, to potentially gain information and/or execute arbitrary code. This means an attacker needs to entice a user to open a specifically crafted project file. The business impact could be significant, potentially leading to data breaches, system compromise, or denial of service. The likelihood of exploitation is moderate, dependent on the attacker successfully delivering the crafted project file to a user. Ease of exploitation is also moderate, requiring a crafted file, but not necessarily complex network access. The vulnerability impacts confidentiality (potential data exposure), integrity (potential for data modification or code execution), and availability (potential for system crashes or resource exhaustion). The CVSS v3.1 score of 7.8 (HIGH) further reinforces the risk level.

      2. Potential Attack Scenarios
      An attacker could leverage this vulnerability through a spear-phishing campaign targeting V-Server users. The attack vector is a specially crafted project file attached to an email, disguised as a legitimate project update or collaboration file. The attack process involves the user opening the malicious project file within V-Server. This triggers the out-of-bounds write, allowing the attacker to potentially overwrite adjacent memory locations. The potential outcome is arbitrary code execution, giving the attacker control over the affected system. This could lead to data theft, installation of malware, or disruption of V-Server services. A secondary scenario involves a compromised internal system already having access to V-Server project files; the attacker could modify a commonly used project file to include the exploit, spreading it to other users when they open it.

      3. Mitigation Recommendations
      Immediate action should be taken to patch V-Server to a version later than v4.0.12.0. Fujielectric provides updates and download information on their website: https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php. In the short term, users should be cautious when opening project files from untrusted sources. Consider implementing application whitelisting to restrict which applications can execute, providing an additional layer of protection. Regularly scan V-Server systems for vulnerabilities using a vulnerability scanner. Implement strong access controls to limit the potential blast radius if a system is compromised. Train users on recognizing phishing attempts and suspicious project files. Consider a review of all V-Server project files to identify potentially compromised files.

      4. Executive Summary
      V-Server, a product used by FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd., is vulnerable to an out-of-bounds write, potentially allowing attackers to gain control of affected systems. This vulnerability requires a user to open a specially crafted project file, but if successful, can lead to data theft, system compromise, or service disruption. The risk is considered high, with a CVSS score of 7.8. We recommend immediately patching V-Server to the latest version available from Fujielectric (https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php). Users should also be vigilant when opening project files from external sources. Addressing this vulnerability is crucial to protecting sensitive data and ensuring the continued availability of V-Server services. Proactive patching and user awareness are key to mitigating this risk.

      CVE-2022-47908

      Severity: HIGH

      Description: Stack-based buffer overflow vulnerability in V-Server v4.0.12.0 and earlier allows a local attacker to obtain the information and/or execute arbitrary code by having a user to open a specially crafted project file.

      CVSS Score: N/A

      Priority

      D

      CISA Data

      EPSS Data

      • EPSS: 0.001020000
      • Percentile: 0.277430000
      • Date: 2026-05-29

      ExploitDB

      No data available.

      HackerOne Data

      • Rank: 9580
      • Reports submitted count: 0
      • Unknown: 0
      • None: 0
      • Low: 0
      • Medium: 0
      • High: 0
      • Critical: 0

      GitHub PoCs

        Nuclei Templates

        No data available.

        VulnCheck Data

        Affected Products:

        • FUJI ELECTRIC CO., LTD. and Hakko Electronics Co., Ltd. V-Server - Versions: v4.0.12.0 and earlier

        References:

        Risk Assessment

        1. Risk Assessment
        The vulnerability, CVE-2022-47908, is a stack-based buffer overflow in Fuji Electric’s V-Server software versions 4.0.12.0 and earlier. This vulnerability allows a local attacker, with user-level access, to potentially gain information or execute arbitrary code by opening a specifically crafted project file. The risk is considered high, given a CVSS v3.1 score of 7.8. The business impact could range from data breaches and system compromise to disruption of operations if the V-Server is critical to production processes. The likelihood of exploitation is moderate, as it requires a user to open a malicious file, but the ease of exploitation is relatively high once the file is opened, as buffer overflows are often straightforward to exploit. Impacts to confidentiality, integrity, and availability are all potentially high, as arbitrary code execution allows an attacker to control the affected system. The EPSS score of 0.001020000 suggests a relatively low, but not insignificant, probability of exploitation in the wild.

        2. Potential Attack Scenarios
        A potential attack scenario involves a malicious actor crafting a V-Server project file specifically designed to overflow the stack buffer. The attacker could then deliver this file to a user via email, shared network drive, or USB drive. When the user opens the project file within V-Server, the overflow occurs, potentially overwriting adjacent memory locations. The attacker could leverage this overflow to inject and execute their own code, gaining control of the V-Server process. This control could then be used to steal sensitive data stored or processed by V-Server, modify project data leading to incorrect outputs, or even escalate privileges to gain broader system access. The user interaction (opening the file) is required, making it a targeted attack, but the impact of successful exploitation is significant.

        3. Mitigation Recommendations
        The primary mitigation is to upgrade V-Server to a version later than 4.0.12.0. Fuji Electric has released updates to address this vulnerability. Immediate action should be taken to patch all instances of V-Server in production and test environments. Further, user awareness training should be conducted to educate users about the risk of opening project files from untrusted sources. Implement file extension verification to ensure that only expected project file types are opened within V-Server. Consider utilizing a vulnerability scanner to identify any remaining instances of the vulnerable software within the environment. Relevant resources include the Fuji Electric support website (https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php) and the JPCERT/CC advisory (https://jvn.jp/en/vu/JVNVU92811888/index.html).

        4. Executive Summary
        V-Server, a software product used by Fuji Electric, contains a stack-based buffer overflow vulnerability (CVE-2022-47908) that could allow an attacker to gain control of the system by tricking a user into opening a malicious project file. A successful attack could lead to data theft, system disruption, or compromise of critical processes. While the attacker needs a user to open the malicious file, the potential impact is high. We recommend upgrading V-Server to the latest version as quickly as possible to mitigate this risk. This is a priority update, as the vulnerability has a CVSS score of 7.8, indicating a significant threat. Prompt patching will protect our data and ensure continued operation of systems relying on V-Server.