Sploit.io - Search

Product: e-Alert, version: >= All, < 2.7

CVE-2022-0922

Severity: MEDIUM

Description: The software does not perform any authentication for critical system functionality.

CVSS Score: 6.5

Priority

B

CISA Data

EPSS Data

  • EPSS: 0.000430000
  • Percentile: 0.136430000
  • Date: 2026-05-31

ExploitDB

No data available.

HackerOne Data

  • Rank: 9590
  • Reports submitted count: 0
  • Unknown: 0
  • None: 0
  • Low: 0
  • Medium: 0
  • High: 0
  • Critical: 0

GitHub PoCs

    Nuclei Templates

    No data available.

    VulnCheck Data

    Affected Products:

    • Philips e-Alert - Versions: All

    References:

    Risk Assessment

    1. Risk Assessment
    The vulnerability CVE-2022-0922 affects Philips e-Alert software versions prior to 2.7. The core issue is a lack of authentication for critical system functionality. This means an attacker with adjacent network access can potentially disrupt the system without needing valid credentials. The base CVSS score is 6.5 (Medium), indicating a moderate level of risk. The EPSS score is quite low, suggesting a relatively low probability of exploitation in the wild, but the high availability impact makes it significant if exploited. The business impact could range from service disruptions and process delays to potential impact on patient monitoring if the e-Alert system is integrated with critical medical devices. Likelihood of exploitation is moderate, given the adjacent network access requirement, but ease of exploitation is high because no authentication is needed. Confidentiality and integrity are not directly impacted, but availability is significantly affected as the attacker can cause high disruption.

    2. Potential Attack Scenarios
    An attacker on the same network segment as a Philips e-Alert device running a vulnerable version can leverage this vulnerability to cause a denial of service. The attacker could send crafted network requests directly to the e-Alert device, triggering critical system functionality without authentication. This could overload the device’s resources, causing it to become unresponsive or crash. If the e-Alert system is used for critical monitoring or alerting, this could lead to missed alarms or delayed responses, potentially impacting patient care or operational efficiency. The attack vector is adjacent network, meaning the attacker needs to be on the same network segment (e.g., same VLAN) as the e-Alert device. The attack process involves sending specially crafted network packets to the device, bypassing the typical authentication mechanisms. The potential outcome is a denial of service, potentially impacting critical monitoring or alerting functionality.

    3. Mitigation Recommendations
    The primary mitigation is to upgrade the Philips e-Alert software to version 2.7 or later. Philips has released updates to address this vulnerability. In the interim, network segmentation can be used to limit access to the e-Alert system to only authorized personnel and devices. Implement strong network access controls, such as firewalls and VLANs, to restrict access to the e-Alert system from untrusted network segments. Monitor network traffic for unusual activity targeting the e-Alert device. Refer to the CISA advisory ICSMA-22-088-01 for more detailed guidance: https://www.cisa.gov/uscert/ics/advisories/icsma-22-088-01. Implement physical security measures to limit physical access to the devices.

    4. Executive Summary
    Philips e-Alert software versions prior to 2.7 are vulnerable to a critical flaw allowing attackers on the same network to disrupt system functionality without authentication. While the probability of exploitation may be relatively low, the potential impact on availability is high, potentially impacting monitoring and alerting capabilities. We recommend upgrading to version 2.7 or later as soon as possible. In the meantime, implement network segmentation and access controls to limit potential disruption. Addressing this vulnerability is important to ensure the reliable operation of the e-Alert system and minimize potential impact on critical processes or patient care. This is a medium-severity vulnerability that requires prompt attention to avoid potential service disruptions.